The F1500-UPS E battery backup designed exclusively for audio/video professionals and home theatre aficionados.
Protection
Typical UPS systems Feature antiquated surge suppression technologies that can cause as much damage and annoying lock-ups as they attempt to prevent. Only Furman offers battery back-up with our road-proven SMP non-sacrificial, zero ground contamination surge suppression technology and EVS Extreme Voltage Shutdown. After all, the most robust battery cannot function if the accompanying circuits are damaged. With Furman's F1500-UPS E, you can expect years of trouble free operation*.
Filtration
While other UPS devices Feature AC line filters suitable for an I.T. closet, only Furman employs our exclusive Linear Filtering Technology (LiFT). This advanced noise filtering technology assures that today's ultra-wide dynamic range is maintained as it must be" pristine. Remember, less AC noise equals greater content, greater resolution, and higher definition.
True Sine Wave Output
The F1500-UPS E provides True Sine Wave output when in battery backup mode, ensuring the utmost reliability to all connected equipment while running on battery power.
Expandability
At 1500VA, the F1500-UPS E provides substantial backup time for most critical digital A/V components. If more runtime is needed, a 1500VA battery pack (BATT1500-EXT, sold separately) may be used to further increase runtime (up to four times) as the application demands.
BlueBOLTdeg. Cloud Based IP Control/Monitoring and Serial Programmability & Control
BlueBOLT compatibility (via BlueBOLT-CV1 interface card, sold separately), offers remote control over any Internet connection via a truly plug-and-play, hosted, web-based graphical user interface, with full control and power monitoring functionality. RS-232 control with a wide range of commands to interface with an existing control unit is included. Dual programmable IR control allows the unit to send a shut down command to remote components in the event of a blackout.
Typical Backup Components
Given the nature of battery backup technology, high-current audio and video components such as power amplifiers, powered subwoofers, and high- wattage displays are not recommended for use with the F1500-UPS E. Not only will these components drain battery power quite rapidly, line impedance will be raised due to the F1500-UPS E's (or any) AVR and AC to DC inverter, which can induce current compression and noticeably diminish performance with high-current A/V equipment. The following components are Ideal for use with the F1500-UPS E:
DAWs
Satellite Receivers
Cable Boxes
Digital Video Recorders
Media Servers
External Hard Drives
Lamp Based Video Displays
Control Systems
For power management of other components, Furman recommends Classic, Prestige or Reference i Series Power Conditioners. For high-current components such as power amplifiers and powered subwoofers, solutions Featureing Furman's exclusive Power Factor Technology are Ideal.
Approximate Run Time, 1500VA *
Satellite Receiver or Cable Box = 80 Minutes
Media Server + Control System = 40 Minutes
Digital Mixing Console (24 Channel) = 20 minutes
DAW Computer + Digital I/O + External Hard Drive + 24LCD Monitor = 12 Minutes

UNINTERRUPTIBLE POWER SUPPLY BATTERY BACKUP / POWER CONDITIONER

SKU: F1500-UPS
$3,545.00Price
  • 1500VA Battery Backup maintains critical data and allows orderly shutdown in the event of a power outage Series Multi-Stage Protection (SMP) provides virtually maintenance-free AC surge suppression Linear Filtering Technology (LiFT) for unequaled audio/video clarity Extreme Voltage Shutdown (EVS) protects your equipment from sustained overvoltage conditions Dual Learning IR Blasters allow safe shutdown of remote components RS-232 Interface provides custom open source programming and control USB Interface Critical Load Management AVR voltage regulation provides a consistent voltage output BlueBOLTdeg. technology (with optional TCP/IP card, sold separately) provides remote control to reboot components, power equipment on or off, and monitor power quality from anywhere in the world Optional rack ears included Nominal Line Voltage: 220 VAC 230 VAC 240 VAC UPS Input Voltage: 156 - 274 VAC 166 - 284 VAC 176 - 294 VAC Frequency: 50/60 Hz"3% (auto-sensing) UPS Output Voltage: 220 VAC"10% 230 VAC"10% 240 VAC"10% Frequency: 50/60 Hz"1% (adaptive) Current Rating: 6.82 A 6.53 A 6.25 A UPS Output Capacity: 1500 VA, 900W, cos 0.6 UPS Backup Time: 12 minutes at full load, 32 minutes at half load UPS Transfer Time: < 4ms Automatic Voltage Regulation Standard Mode Capture Range: 160-276 VAC 170-286 VAC 180-296 VAC Standard Mode Output Range: 220" 24 VAC 230" 24 VAC 240" 24 VAC Sensitive Mode Capture Range: 177-254 VAC 187-254 VAC 197-264 VAC Sensitive Mode Output Range: 220" 12 VAC 230" 12 VAC 240" 12 VAC Nominal Line Voltage: 220 VAC 230 VAC 240 VAC Surge Protection Technology: Non-sacrificial SMP (Series Multi-Stage Protection) Overvoltage Shutoff, fast rise: 305 VAC Overvoltage Shutoff, slow rise: 265 VAC 275 VAC 285 VAC Noise Attenuation: INPUT 10 dB @ 10kHz, 40 dB @ 100 kHz, 50 dB @ 500kHz Linear Attenuation Curve: From 0.05 - 100 Ohms line impedance UPS Physical Attributes UPS Topology: Line Interactive Temperature Rating: 0 ~ 40deg.C / 40deg.C maximum for ambient operation Mass: 32.5 Kg / 72 lbs. Dimensions: 89mm H x 487.7mm L x 444.5mm D / 3.5" H x 19.2" L x 17" W Battery: Sealed Lead-Acid Plug: 1mmdeg. x 3.3m, Detachable male Schuko with retention clips Display: Alphanumeric 2 X 20 LCD STN positive image, Backlit blue
  • This item is typically in stock with our supplier and ships within 1-5 Days, though product lead times may vary.

    Please contact us prior to ordering to confirm Availability

bottom of page